TM 9-2320-209-34-2-3 FRAME 9 1. Take out terminal screw (1) on overheat thermostat (2). Put on two over- heat thermostat electrical leads (3 and 4). Screw in and tighten terminal screw (1). 2. Do step 1 again for terminal screw (5) on overheat thermostat (2) and electrical leads (6 and 7). 3. Take out terminal screw (8) on terminal strip (9). Put on fuel control valve electrical lead (10) on terminal strip (9). Screw in and tighten terminal screw (8). GO TO FRAME 10 21-59