TM 9-2320-209-34-2-3 (5) Fuel control valve. FRAME 1 WARNING Dry cleaning solvent is flammable. Do not use near an open flame. Keep a fire extinguisher nearby when sol- vent is used. Use only in well-ventilated places. Fail- ure to do this may result in injury to personnel and damage to equipment. CAUTION Do not dip fuel control valve (1) in dry cleaning solvent. Electrical parts may be damaged by doing so. 1. Wipe fuel control valve (1) clean with a clean cloth dipped in dry cleaning solvent. Wipe fuel control valve (1) dry. 2. Inspect fuel control valve (1) for cracked or broken parts. Go to step 6 if cracks or breaks are found. 3. Inspect electrical leads (2, 3, 4, 5, 6, and 7) for broken or frayed insulation or damaged connectors on the ends. Go to step 6 if any electrical leads or connectors are bad. 4. Using an ohmmeter, check continuity through heater. Place on terminal (8) and the other ohmmeter lead on terminal (9). be closed. If circuit is open, go to step 6. 5. If fuel control valve (1) passes tests, to go frame 2. If you fuel control valve, do step 6. NOTE Electrical leads (2 and 7) must be used on new fuel trol valve. one ohmmeter lead Circuit should must get a new con- 6. Unscrew and take off nut (10). Take off electrical lead (2) and slide off electrical lead (7). Get a new fuel control valve. GO TO FRAME 2 21-38
