TM 9-2320-209-34-2-3 FRAME 6 1. Take off electrical lead (1) from fuel control valve body (2) and from pin A (3) of wiring harness connector (4). 2. Take off electrical lead (5) from fuel control valve leads (6) and from pin B (7) of wiring harness connector (4). 3. Take off fuel supply line (8) from fuel inlet fitting (9). NOTE If these tests on fuel control valve were done as part of cleaning, inspection, and repair, skip step 4, go to para 21-6d (5), frame 2. 4. Put fuel control valve (2) on heater (10). Refer to para 21-6e, frame 8, frame 9, and frame 12. END OF TASK 21-8