TM 9-2320-209-34-2-2 FRAME 2 NOTE Readings must be within limits given in table 17-6. If readings are not within given limits, throw away part and get a new one. 1. Measure fit of bearing (1) on shaft (2). GO TO FRAME 3 Table 17-6. Power Leveler Assembly Wear Limits Size and Fit Index of New Parts Wear Limit Number Item /Point of Measurement (inches) (inches) 1 and 2 Fit of bearing on shaft 0.001 to 0.005 None 17-618