TM 9-2320-209-34-2-2 FRAME 3 1. 2. 3. 4. 5. Put on all wires (1) in power switch box (2) as tagged. Take off tags. Pull three wires (3) through nipple and bushing in power switch box (2) as tagged. Take off tags. Connect three wires (3) to STOP and START switch (4) as tagged. Take off tags. Close power switch door (5). Put on STOP and START switch cover (6) and put in two screws (7). NOTE Follow-on Maintenance Action Required: 1. Replace circuit breaker box. Refer to para 17-36. 2. Replace dome light switch. Refer to TM 9-2320-209-20. 3. Replace converter. Refer to para 17-37. END OF TASK 17-458