TM-9-2320-209-34-2-2 Page 471

TM-9-2320-209-34-2-2 Maintenance Part 2 for M44A1 and M44A2 Series Trucks

Page 471 of 899

TM 9-2320-209-34-2-2 1. Reach behind loose panel (1) and take off three converter plug wires (2). 2. Feed all wires (3) through panel (1). 3. Move panel (1) aside and pull back insulation (4) until eight nuts (5) are seen. Soldier A 4. Working inside truck, hold eight nuts (5). Soldier B 5. Working outside truck, take out eight screws and lockwashers (6). Take off four folding steps (7). END OF TASK 17-454