TM 9-2320-209-34-2-1 (2) Cleaning, inspection, and repair. FRAME 1 1. 2. 4. WARNING Dry cleaning solvent is flammable. Do not use near an open flame. Keep a fire extinguisher nearby when sol- vent is used. Use only in well-ventilated places. Failure to do this may result in injury to personnel and damage to equipment. Clean compensator body (1) and cage cover (2) with dry cleaning solvent. Check that all finished surfaces on compensator body (1) and cage cover (2) have no scratches. If finished surfaces are scratched, rub out any scratches with honing stone. If scratches will not rub out easily, get a new compensator body (1) and cage cover ( 2). NOTE Do not take out tube fitting (3) or pipe plug (4). Check that tube fitting (3) and pipe plug (4) are not damaged. If air tube fitting or pipe plug is damaged, get a new compensator body (1) and cage cover (2). GO TO FRAME 2 12-29