TM 9-2320-209-20-3-4 c. Cleaning, Inspection, and Repair. FRAME 1 WARNING 1. Clean all Dry cleaning solvent is flammable. Do not use near an open flame. Keep a fire extinguisher nearby when solvent is used. Use only in well-ventilated places. Failure to do this may result in injury to personnel and damage to equipment. Eye shields must be worn when using compressed air. Eye injury can occur if eye shields are not used. parts with solvent. 2. Using compressed air, clean magnet inside of cover (1). 3. Check that cover (1) has no cracks or breaks. If cover is damaged, throw it away and get a new one. 4. Check that sediment strainer (2) has no cracks, breaks, tears or bends. If sediment strainer is damaged, throw it away and get a new one. END OF TASK 23-61