TM 9-2320-209-20-3-4 FRAME 2 1. 2. 3. Put diverter duct (1) on air inlet adapter (2). Using screwdriver, tighten duct clamp (3). Put adapter cable assembly (4) through cable clamp (5) and put looped end of cable on shaft (6). Using screwdriver, tighten screw (7). NOTE Follow-on Maintenance Action Required: 1. Adjust control cable. Refer to para 23-8. 2. Close hood and left side panel. Refer to TM 9-2320-209-10. END OF TASK 23-12