TM 9-2320-209-20-3-3 c. Replacement. FRAME 1 1. 2. 3. Push in lamp (1) and turn to right. Close light door (2). Using screwdriver, screw in and tighten screw (3). NOTE Follow-on Maintenance Action Required: 1. Reconnect battery ground cable. Refer to Part 1, para 7-58. 2. Turn on 24-volt dome light circuit breaker. Refer to TM 9-2320-209-10. END OF TASK 18-364