TM 9-2320-209-20-3-3 FRAME 2 1. Close light door (1). 2. Using screwdriver, screw Follow-on in and tighten lockscrew (2). NOTE Maintenance Action Required: 1. If 24-volt dome light assembly was worked on, reconnect battery ground cable. Refer to Part 1, para 7-58. 2. If 115-volt dome light assembly was worked on, turn on 115-volt circuit breaker. Refer to TM 9-2320-209-10. END OF TASK 18-362