TM 9-2320-209-20-3-3 FRAME 2 1. Take out strainer (1) from strainer housing (2). WARNING Dry cleaning solvent is flammable. Do not use near an open flame. Keep a fire extinguisher nearby when solvent is used. Use only in well-ventilated places. Failure to do this may result in injury to personnel and damage to equipment. 2. Using solvent, clean strainer (1). Dry with compressed air. Make sure there is no dirt left in strainer. 3. Using solvent, clean flange (3). Use scraper, if needed, to get off all gasket pieces. Do not get any gasket pieces in strainer housing (2). END OF TASK 18-150