TM 9-2320-209-20-3-1 c. Replacement. FRAME 1 1. 2. 3. 4. Put starter adapter gasket (1) over three studs (2) and against mounting flange (3). Straight edge of gasket must be at bottom. WARNING Dry cleaning solvent is flammable. Do not use near an open flame. Keep a fire extinguisher nearby when solvent is used. Use only in well-ventilated places. Failure to do this may result in injury to personnel and damage to equipment. Before putting in starter, using solvent, clean starter adapter (4) of starter. Put starter adapter (4) over three studs (2) and against starter adapter gasket (1). Put starter gasket (5) over three studs (2) and against starter adapter (4). Straight edge of gasket must be at bottom as shown. GO TO FRAME 2 7-51 I