TM 9-2320-209-20-3-1 FRAME 5 1. 2. 3. Push generator (1) toward engine and slip two V-belts (2) around pulley (3). NOTE Do not hook up electrical connector to generator at this time. Polarization procedure must be done first. Put lockwasher (4) and key washer (5) on bolt (6). Put bolt (6) through adjustment bracket (7), and screw bolt into generator flange (8) finger tight. NOTE Bolt (6) is not tightened until fan belt adjustment has been done. NOTE Follow-on Maintenance Action Required: 1. Adjust fan belt. Refer to para 6-9. 2. Do polarization procedure. Refer to para 7-3d. 3. Start engine and check that battery-generator indicator is in the green area. Stop engine. Refer to TM 9-2320-209-10. 4. Close hood and right side panel. Refer to TM 9-2320-209-10. END OF TASK 7-10