TM 9-2320-209-20-3-1 FRAME 3 1. Using spring scale (l), pull upper end of bar (2) with force of 50 pounds and using 9/16-inch wrench, tighten capscrew (3). Take out bar. 2. Push on belts (4) at point midway between coolant pump pulley (5) and generator pulley (6). Belt should give about 3/4-inch at this point. NOTE Follow-on Maintenance Action Required: Close hood. Refer to TM 9-2320-209-10. END OF TASK TA 047640 6-48