TM 9-2320-209-20-3-1 FRAME 2 1. 2. 3. 4. GO Take off WARNING Dry cleaning solvent is flammable. Do not use near an open flame. Keep a fire extinguisher nearby when solvent is used. Use only in well-ventilated places. Failure to do this may result in injury to personnel and damage to equipment. protective cover from hole in tank. Clean mating flanqes of fuel pump and tank with dry cleaning solvent. Apply thin coat of sealer com- pound to threads of fuel fittings before assembling. Put new Put fuel gasket (1) on fuel tank (2) and aline 10 holes. CAUTION Be very careful when putting fuel pump in tank so that electrical cable shield will not scrape hole. Damage to the shield could cause electrical failure. pump (3) in tank (2) as shown. Aline holes in pump with holes - in gasket (l) and tank (2) . Using screwdriver, screw in and tighten 10 screws (4) with 10 lockwashers (5) through holes in pump mounting flange. TO FRAME 3 TA 047132 4-49