TM-9-2320-209-20-2-1 Troubleshooting Part 1 for M44A1 and M44A2 Series Trucks
Page 279 of 645
TM 9-2320 -209-20-2-1 • • • Ž Set multimeter to measure +24 volts DC. Refer to test equipment procedures index Put multimeter - lead on a good ground Put muItimeter + lead on contact A of battery to regulator cable connector Read multimeter. Multimeter should measure +24 volts DC Does multimeter measure +24 volts DC? Clean battery terminals and cable ends • Take off battery cables from battery terminals. Refer to Vol 3, chapter 7, para 7-56 • Clean battery terminals and cable ends. Refer to Vol 3, chapter 7, para 7-55 • Put battery cables back on battery terminaIs. Refer to Vol 3, chapter 7, para 7-56 NO GO Figure 25-2 (Sheet 11 of 13) TA 114244 25-37