TM-9-2320-209-20-2-1 Troubleshooting Part 1 for M44A1 and M44A2 Series Trucks
Page 252 of 645
TM 9-2320-209-20-2-1 Check lead 214 terminal of magnetic starter relay SOLDIER B: ● ● SOLDIER A: ● SOLDIER B: ● Put multimeter - lead on a good ground Put multimeter + lead on lead 214 terminal of magnetic starter relay Step on starter button Read multimeter. Multimeter should measure +24 volts DC Does multimeter measure +24 volts DC? MAGNETIC STARTER ● Remove and replace magnetic starter relay ● Set ACCESSORY switch to OFF ● Remove and replace magnetic starter relay. Refer to Vol 3, chapter 7, para 7-7 GO 25-10 TA 114217 Figure 25-1 (Sheet 9 of 25)