TM 9-2320-209-20-2-1 From step 11 Check for +24 volts DC (from batteries) through magnetic starter relay SOLDIER B: ● ● ● SOLDIER A: ● SOLDIER B: ● Set multimeter to measure +24 volts DC. Refer to test equipment procedures index Put multimeter - lead on a good ground Put multimeter + lead on lead 6 terminaI of magnetic starter relay Step on starter button Read multimeter. Multimeter should measure +24 volts DC Does multimeter measure +24 volts DC? MAGNETIC ● Replace lead 6 ● Set ACCESSORY switch to OFF Replace lead 6. Tell direct support maintenance Figure 25-1 (Sheet 8 of 25) 25-9