TM-9-2920-257-30&P Maintenance and Parts Manual for 200 Amp M113 Generator Download

Page 15 of 111

TM 9-2920-257-30&P Table 2-1. Generator Troubleshooting - Continued MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION Step 8. Connector Pin and Lead Continuity Check. Check continuity of pins and leads in connector assembly according to figure 2-6. If the ohmmeter readings are greater than 0, connector assembly is defective. Replace connector assembly in accordance with paragraph 3-3 and go to step 9. 2-8 Figure 2-6.