TM-9-2920-257-30&P Maintenance and Parts Manual for 200 Amp M113 Generator Download

Page 95 of 111

TM 9-2920-257-30&P 16. Add incremental loads up to 200 amps. Voltage should remain constant. 17. If 28 volts cannot be sustained at various settings, regulator is defective. 18. Reduce loads one at a time, until load is zero at completion of test. 19. Reduce test stand speed to 1000 RPM. 20. Press STOP button. Wait for test stand to come to a complete stop. 21. Return test stand switches and controls to base settings (para E-3). 22. Remove generator and regulator from test stand. Figure E-1. 200 AMP Generator Performance Curves Change 1 E-7/(E-8 Blank)