TM-9-2920-257-30&P Maintenance and Parts Manual for 200 Amp M113 Generator Download
Page 64 of 111
TM 9-2920-257-30&P (13.) Remove retaining ring (20) from core and shaft (4). (14.) Using an arbor press (item 4, App D), remove the core and shaft (4) from the front housing (18) by pressing shaft down through the front bearing (21). (15.) Remove two retaining rings (22 and 23) from front housing (16). (16.) Support front housing on blocks and with an arbor press (item 4, App D), remove front bearing (21). 3-34 Change 1