TM-9-2920-257-30&P Maintenance and Parts Manual for 200 Amp M113 Generator Download
Page 62 of 111
TM 9-2920-257-30&P (7.) Using a puller (item 7, App D.), remove rear bearing (15) from core and shaft. (8.) Remove six flange nuts (13) from core and shaft studs. (9.) Use three 10-32 UNF X 2 inch long machine screw as jackscrews. Install three screws in threaded holes of rotor end plate. Pull rotor from core by gradually working screws against core in sequence. 3-32 Change 1