TM 9-2920-257-30&P CAUTION Care must be taken to ensure terminals do not touch any portion of drive end housing assembly. Failure to do so will result in damage to equipment. (d) Secure two heavy black connector leads and one thin red lead from printed circuit panel assembly (7) to Positive rectifier heat sink using two brass bolts (1). Tighten bolts securely. (12) Install cover plate on drive end housing assembly (fig. 3-1). NOTE When assembling cover plate, use black paint outline and scribe marks on drive end housing assembly as a guide to ensure proper orientation of cover on housing. (a) Install cover plate (6) on front face of drive end housing assembly (21) using six screws (4) and eight SCreWS (5). (b) Tighten screws securely. (13) Install fan (fig. 3-1). (a) Install key (3) in key slot of shaft of rotor (14). (b) Clamp pulley end of shaft of rotor (14), with key (3) inserted in key-slot, in vise with soft-jaw caps to keep generator shaft from turning. 3-27