TM-9-2920-257-30&P Maintenance and Parts Manual for 200 Amp M113 Generator Download
Page 56 of 111
TM 9-2920-257-30&P NOTE Have helper assist in steps (d) and (e) below. (d) Install combined circuit panel assembly unit (11) and brush assembly unit (12) in drive end housing assembly (6). Tighten four screws (1). (e) Install leads as follows, using figure 3-10 as a guide for making lead connections. 1 . Secure short black lead from printed circuit panel assembly (5) to housing ground hole in drive end housing assembly (6) using screw (11, fig. 3-2). Tighten screw securely. 2 . Secure each of the three long black leads from printed circuit panel assembly (5) to each of the three stator terminal studs using three nuts (10, fig. 3-2). Route leads in cavity of drive end housing assembly (6) along with negative rectifier leads. Torque nuts to 12-14 pound-feet. (11) Install mounting plate and connector assembly to drive end housing assembly (fig. 3-2). Use figure 3-2 and figure 3-12 to make lead connections. (a) Route two heavy black connector leads through brush holder cavity in drive end housing assembly (6) to positive rectifier area of drive end housing assembly. (b) Secure three thin black connector leads and two black brush leads to printed circuit panel assembly (7) using three screws (8) and lock washers (9). Tighten screws securely. (c) Secure connector assembly (4) and mounting plate (5) on drive end housing assembly (6) using four screws (2) and lock washers (3). Tighten screws securely. 3-26