TM-9-2920-257-30&P Maintenance and Parts Manual for 200 Amp M113 Generator Download

Page 54 of 111

TM9-2920-257-30&P (c) Insert four screws (7) with lock washers (8) through holes in anti-drive end housing (9) and thread them into holes in drive end housing assembly (21). Tighten screws securely. (10) Install brush holder, brushes, and printed circuit panel assembly in drive end housing assembly (fig. 3-3). Use figure 3-12 as a guide when making lead connections. (a) Assemble brush assembly unit (12) as follows: 1 . Install two brush assemblies (9) into two holes of brush holder (10), with tabs at end of brush springs placed in shallow cavities of brush holder. 2 . Place brush cover (8) in position on top of brush holder (10), routing brush leads through holes in brush cover. (b) Assemble circuit panel assembly unit (11) as follows: 1 . Assemble four screws (1), lock washers (2), washers (3), and insulations washers (4) on top of printed circuit panel assembly (5). . 2 . Push four screws (1) through printed circuit panel assembly (5). Place a spacer (7) on each of the four screws. (c) Assemble printed circuit panel assembly unit (11) to brush assembly unit (12). 1 . Route black leads from two brush assemblies (9) through hole in printed circuit panel assembly (5). Route four screws (1) from printed circuit panel assembly 2 . unit (11) through four holes in brush assembly unit (12). 3-24