TM-9-2920-257-30&P Maintenance and Parts Manual for 200 Amp M113 Generator Download
Page 48 of 111
TM 9-2920-257-30&P CAUTION Insulator can crack if not properly alined in depression in drive end housing assembly. Carefully aline insulator in depression. (d) place insulator (18) over stator terminal studs in drive end housing assembly (21) and secure with six spring washers (17), three flat washers (16), and nuts (15). Torque nuts to 16-18 pound-feet. (e) Refer to figure 3-10 and connect three negative rectifier leads and three positive rectifier leads to stator terminal studs as follows: 1 . Assemble negative rectifier leads (1, 2, and 3) to stator studs in that order, and secure with three nuts (15). Torque nuts to 12-14 pound-feet. 2 . Assemble positive rectifier leads (4, 5, and 6) to stator terminal studs. Nuts will be installed in step (10)(e) 2 below. (f) Remove stator (19) and drive end housing assembly (21) from anti-drive end housing (9) and place it on workbench with stator facing up. (4) Install roller bearing to anti-drive end housing (fig. 3-1). (a) Place anti-drive end housing (9) in arbor press with exterior of housing facing up. (b) Place roller bearing (12) in position on bearing bore with lettered end of bearing facing up. 3-18