TM-9-2920-257-30&P Maintenance and Parts Manual for 200 Amp M113 Generator Download
Page 40 of 111
TM 9-2920-257-30&P While the rotor is being pressed out of the drive end housing assembly, firmly grasp bottom section of rotor shaft to prevent rotor from dropping. Failure to do this could result in injury to personnel and damage to equipment. (b) Apply pressure on top of rotor shaft to remove rotor (14) from drive end housing assembly (21). (c) Remove spacer (25) from outer seal (24). (8) Remove stator (fig. 3-1). (a) Remove stator (19) and drive end housing assembly (21) from arbor press. Place assembly on top of anti–drive end housing (9) so that drive end housing assembly (21) faces up and stator laminations fit flush in pilot bore of anti-drive end housing to protect stator windings. (b) Remove three rectifier leads from stator terminal studs, and bend leads out of the way to provide access to stator terminal nuts. (c) Remove three nuts (15) used to secure rectifier leads to stator teminal studs. (d) Remove three rectifier leads from stator terminal studs, and bend leads out of the way to provide access to teminal insulator (18). (e) Remove three nuts (15), washers (16), and six spring washers (17) used to secure insulator (18) to stator terminal studs. (f) Remove insulator (18) from stator terminal studs. 3-10 WARNING