TM 9-2920-257-30&P (4) Remove printed circuit panel assembly, brush assemblies, and brush holder (fig. 3-3). (a) Remove three nuts (10, fig. 3-2) securing three long black leads from printed circuit panel assembly (7, fig. 3-2) to three stator terminal studs. (b) Remove screw (11, fig. 3-2) securing short black lead from printed circuit panel assembly (7, fig 3-2) to housing ground hole. (c) Remove four screws (1), lock washers (2), washers (3), and insulation washers (4) securing printed circuit panel assembly (5) to drive end housing (6). CAUTION Brush holder can be damaged if not handled carefully. Handle brush holder carefully. (d) Remove printed circuit panel assembly (5), four spacers (7), brush cover (8), two brush assemblies (9), and brush holder (10) from drive end housing assembly (6). If brush holder binds to drive end housing, tap brush holder with plastic mallet. (5) Remove anti-drive end housing (fig. 3-1). (a) Remove four screws (7) and lock washers (8) used to secure anti-drive end housing (9) and stator (19) to drive end housing assembly (21). NOTE If anti–drive end housing binds to stator, tap housing with plastic mallet. (b) Remove anti-drive end housing (9) from shaft of rotor (14). 3-6