TM 9-2920-257-30&P (2) Remove cover plate (fig. 3-1). NOTE Scribe cover plate and drive end housing assembly before removing cover plate. (a) Remove six screws (4) and eight screws (5) securing cover plate (6) to drive end housing assembly (21). (b) Remove cover plate (6). (3) Remove connector assembly and mounting plate (fig. 3-2). (a) Remove two brass bolts (1) securing two heavy black connector leads and thin red lead to positive rectifier heat sink. (b) Remove four screws (2) and lock washers (3) securing connector assembly (4) and mounting plate (5) to drive end housing assembly (6). Move connector assembly and mounting plate to expose printed circuit panel assembly (7). (c) Remove three screws (8) and three lock washers (9) securing three thin black connector leads and two thin black brush leads to printed circuit panel assembly (7). (d) Remove connector assembly (4) and mounting plate (5) from drive end housing assembly (6). Scribe mounting plate and drive end housing assembly. 3-4