TM-9-2920-257-30&P Maintenance and Parts Manual for 200 Amp M113 Generator Download

Page 100 of 111

TM 9-2920-257-30&P NOTE The length tolerance for all cables is ± 0.25 inch. Legend: 1 Cable - M13486/1-11 (6145-00-538-8219) Terminal - 8689221 (5940-01-170-4956) Band marker - M43436/1-1 (9905-00-752-4649) 2 Cable - M13486-1-7 (6145-00-705-6678 Terminal - MS25036-155 (5940-00-660-3633) Band marker - M43436/1-1 (9905-00-752-4649) 3 Connector, plug, - 8724262 (5935-00-730-7325) Insert, elec - 10874855 (5935-00-784-1701) Nut - 7723309 (5310-00-393-6685) Nut - 7716634 (5975-00-771-6634) AR-Rod - 8724768 (9390-00-485-9885) AR-Rod - 8724763 (9390-00-180-7289) Figure F-7. Generator Test Harness - 19207-12349685 F-5