TM-9-2920-225-34 Technical Manual for M113 Generator Download
Page 59 of 262
TM 9-2920-225-34 c. Disassembly. FRAME 1 1. 2. 3. Take out four screws (1), and take regulator (2) off end bell (3). NOTE Do not take apart voltage regulator (2). No repair can be made. Press bearing (4) from drive end bell (3) by pressing on pulley side of bearing. NOTE Do not take out oil seal (6) unless it is damaged. Take spacer (5) and oil seal (6) from drive end bell (3). Throw away oil seal. GO TO FRAME 2 TA103544 2-43