TM-9-2920-225-34 Technical Manual for M113 Generator Download

Page 38 of 262

e. Inspection and Repair. FRAME 1 Generator is 1. Check that intermediate NOTE nonrepairable if any part is damaged. housing (1) is not cracked or broken. 2. Measure intermediate housing bearing bore (2). Bore must be 1.2489 to 1.2495 inches. 3. Check that retaining ring (3), felt retainer (4), felt washer (5), felt retainer (6) , and rotor shaft bearing lip seal (7) are not damaged or worn. END OF TASK TA103521 2-22