TM-9-2920-225-34 Technical Manual for M113 Generator Download
Page 240 of 262
TM 9-2920-225-34 FRAME 2 1. Hookup rectifier (1)using two special purpose cables (2 and 3). Put leads onto rectifier terminals (4) on test stand as labeled. 2. Put other ends of special purpose cables (2 and 3) into receptacles in rectifier (1). END OF TASK TA 103718