TM 9-2920-225-34 FRAME 4 1. Put positive rectifier (1) in place. 2. Put in three insulating bushings (2). 3. Put in screw (3), lockwasher (4), flat washer (5), and one insulating washer (6). 4. Put in terminal board (7) and capacitor (8) and put in two screws (9), lockwashers (10), and other insulating washer (6). GO TO FRAME 5 TA 103643 2-143