TM-9-2920-225-34 Technical Manual for M113 Generator Download
Page 158 of 262
TM 9-2920-225-34 FRAME 3 I 1. 2. 3. 4. GO Coat insulator mount (1) with sealer compound on both sides. Place insulator mount in housing (2), alining holes. NOTE Housing (2) is marked POS. and NEG. so rectifiers will be put back the right way. Positive rectifier has an epoxy coating for insulation and negative rectifier (3) has no coating. Place negative rectifier (3) in housing (2). Put in two screws (4) and capacitor (5). Put two nuts (6), flat stud (8) . Put capacitor (5) lead TO FRAME 4 washers ( 7), and ground leads on negative rectifier on with nut (8) and lockwasher (10). TA 103642 2-142