TM-9-2920-225-34 Technical Manual for M113 Generator Download
Page 126 of 262
TM 9-2920-225-34 FRAME 2 I 1. 2. 3. 4. Place insulator mount (1) in housing (2) through drive end. Aline all holes in insulator mount. NOTE Positive rectifier (3) has an insulating coat of epoxy. Put positive rectifier (3) on insulator mount (1) with one lead through each hole of housing (2). Put in two screws (4), flat washers (5), insulating washers (6), and in- sulating bushings (7). Put insulating bushing (8) and two insulating washers (9) on positive rectifier stud (10). GO TO FRAME 3 TA 103610 2-110