TM 9-2920-225-34 FRAME 2 I 1. 2. 3. 4. Check that stator (1) and stator terminal (2) are not cracked and that there are no stripped threads or loose pins. If stator or terminal is damaged, generator is nonrepairable. Check that stator (1) has no broken windings or loose connections. Resolder any loose or broken connections. Check that stator (1) has no grounds between three pins (3, 4 and 5) on terminal (2) and outer case of stator. Touch one test probe of multimeter to outer case and other test probe to each pin. If ground is present, generator is nonrepairable. CAUTION Do not use a battery or test lamp test. Reverse battery connection instantly . to make a continuity will burn out diodes Check that stator (1) has continuity between three pins (3, 4 and 5) on terminal (2). Touch test probes of multimeter to pins ( 3 and 4), pins (3 and 5) and pins (4 and 5). If continuity is not made between three pins, generator is nonrepairable. GO TO FRAME 3 TA 103606 2-106