TM-9-2815-205-24 Technical Manual for M113 Engine 6V53 6V53T Download
Page 97 of 856
INSTALLATION - Continued CAUTION Nonmetallic seal must set in groove, or inside screw hole bosses of lower flange, to prevent damage. If seal is not in position, container assembly can damage seal and seal will fail. NOTE Container (NSN 8145-00-138-7809) for model 5063-5299 uses 20 screws, no flat washers, and 20 nuts. Torque screws to 54–59 lb-ft (73–80 N·m). Container (NSN 2815-01-232-9447) uses 24 screws, 24 flat washers, and 24 nuts. Torque screws to 31–37 lb-ft (42–50 N·m). 3. Using two adjustable 2-point slings (Figure 1, Item 2), install upper container half (Figure 1, Item 3), screws (Figure 1, Item 6), flat washers (Figure 1, Item 5), and nuts (Figure 1, Item 4) on lower container half (Figure 1, Item 7). Tighten screws (Figure 1, Item 6) progressively around perimeter of container. Torque screws (Figure 1, Item 6) to values noted above. 4. Allow container to stand for a minimum of 12 hours. Then check humidity indicator (Figure 3, Item 11) and verify that air pressure is maintained. NOTE Under moisture-free conditions, the humidity indicator will show blue in color. Pink indicates excessive moisture in container. 5. If humidity indicator (Figure 3, Item 11) is pink, remove upper container half (Figure 3, Item 3), replace all desiccant bags, and replace container nonmetallic seal (Figure 2, Item 9). Install upper container half (Figure 3, Item 3) and test container as indicated in Steps 3–5. 3 11 MAINT_017 Figure 3. Upper Container Half. END OF TASK END OF WORK PACKAGE TM 9-2815-205-24 0010 0010-5/blank