Page 465 of 856

CLEANING WARNING Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe vapors. Keep away from heat or flame. Never smoke when using cleaning solvent. Failure to comply may result in injury, illness, or death to personnel. Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use only with protective equipment (goggles, face shield, gloves, etc.). Failure to comply may result in injury to personnel. 1. Clean check valve, bracket, clamp, and outer surface of air pump with cleaning solvent and dry with compressed air. 2. Clean ignition coil and cushions with warm water and soap. Dry thoroughly. END OF TASK INSPECTION-ACCEPTANCE AND REJECTION CRITERIA 1. Inspect electrical terminals for damage and corrosion. Remove corrosion with a wire brush. 2. Inspect air hose for cuts, tears, kinks, and damage. 3. Inspect air pump rotor and body for excessive wear, corrosion, or other damage. END OF TASK TM 9-2815-205-24 0074 0074-3