TM-9-2815-205-24 Technical Manual for M113 Engine 6V53 6V53T Download

Page 381 of 856

CLEANING WARNING Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe vapors. Keep away from heat or flame. Never smoke when using cleaning solvent. Failure to comply may result in injury, illness, or death to personnel. Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use only with protective equipment (goggles, face shield, gloves, etc.). Failure to comply may result in injury to personnel. Clean air inlet housing with cleaning solvent and dry with compressed air. END OF TASK INSPECTION-ACCEPTANCE and REJECTION CRITERIA Inspect transducer for damaged wires, connector, and threads. END OF TASK INSTALLATION NOTE Three air inlet housing screws were removed during removal of fuel line clip and air pump bracket. 1. Install new screen (Figure 1, Item 7), air inlet housing (Figure 1, Item 9), nine flat washers (Figure 1, Item 4), nine new lockwashers (Figure 1, Item 3), two mid-sized screws (Figure 1, Item 1), three long screws (Figure 1, Item 2), and four short screws (Figure 1, Item 6) on blower (Figure 1, Item 8). Torque screws to 16–20 lb-ft (22–27 N·m). 2. Install transducer (Figure 1, Item 5) in air inlet housing (Figure 1, Item 9). END OF TASK TM 9-2815-205-24 0058 0058-3