TM-9-2815-205-24 Technical Manual for M113 Engine 6V53 6V53T Download
Page 377 of 856
CLEANING WARNING Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe vapors. Keep away from heat or flame. Never smoke when using cleaning solvent. Failure to comply may result in injury, illness, or death to personnel. Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use only with protective equipment (goggles, face shield, gloves, etc.). Failure to comply may result in injury to personnel. Clean air inlet housing with cleaning solvent and dry with compressed air. END OF TASK INSPECTION-ACCEPTANCE and REJECTION CRITERIA Inspect parts for wear or damage. END OF TASK INSTALLATION NOTE Angle bracket (Figure 1, Item 2) mounts on right side, third hole from rear of air inlet housing. Three air inlet housing screws were removed during removal of fuel line clip and air pump bracket. 1. Install new screen (Figure 1, Item 7) (with wire side toward blower), angle bracket (Figure 1, Item 2), air inlet housing (Figure 1, Item 5), nine new lockwashers (Figure 1, Item 4), and nine screws (Figure 1, Item 3) on blower (Figure 1, Item 8). Torque screws to 16–20 lb-ft (22–27 N·m). 2. If removed, install plug (Figure 1, Item 1) and plug (Figure 1, Item 6) in air inlet housing (Figure 1, Item 5). END OF TASK TM 9-2815-205-24 0057 0057-3