TM-9-2815-205-24 Technical Manual for M113 Engine 6V53 6V53T Download

Page 373 of 856

CLEANING WARNING Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe vapors. Keep away from heat or flame. Never smoke when using cleaning solvent. Failure to comply may result in injury, illness, or death to personnel. Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use only with protective equipment (goggles, face shield, gloves, etc.). Failure to comply may result in injury to personnel. Clean air inlet housing and adapter with cleaning solvent and dry with compressed air. END OF TASK INSPECTION-ACCEPTANCE and REJECTION CRITERIA Inspect parts for wear or damage. END OF TASK INSTALLATION 1. Place new air inlet screen (Figure 1, Item 10) on top of blower (Figure 1, Item 9) with wire side to blower. 2. Install air inlet housing (Figure 1, Item 11), five flat washers (Figure 1, Item 7), five new lockwashers (Figure 1, Item 6), short screw (Figure 1, Item 5), two long screws (Figure 1, Item 12), and two mid-sized screws (Figure 1, Item 8) on blower (Figure 1, Item 9) with inlet opening on left side of engine. Torque screws to 16–20 lb-ft(22–27 N·m). 3. Install new gasket (Figure 1, Item 13) and air inlet adapter (Figure 1, Item 1) on air inlet housing (Figure 1, Item 11) with adapter opening toward rear of engine. Align scribe marks on air inlet housing and adapter. Install four flat washers (Figure 1, Item 4), four new lockwashers (Figure 1, Item 3), and four screws (Figure 1, Item 2). Torque screws to 16–20 lb-ft (22–27 N·m). END OF TASK TM 9-2815-205-24 0056 0056-3