TM-9-2815-205-24 Technical Manual for M113 Engine 6V53 6V53T Download
Page 307 of 856
CLEANING WARNING Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe vapors. Keep away from heat or flame. Never smoke when using cleaning solvent. Failure to comply may result in injury or death to personnel. Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use only with protective equipment (goggles, face shield, gloves, etc.). Failure to comply may result in injury to personnel. Clean plugs and metal parts in dry cleaning solvent and dry in compressed air. Clean drain cock with probe. END OF TASK INSPECTION-ACCEPTANCE AND REJECTION CRITERIA 1. Inspect crossover tubes for cracks or damage. 2. Inspect hoses for cracks, wear, or damage. 3. Inspect thermostat as follows: a. Immerse thermostat (Figure 2, Item 8) in suitable container or utility pail of water. Do not allow thermostat to touch bottom of container. 8 MAINT_141 Figure 2. Thermostat Check. TM 9-2815-205-24 0047 0047-3