TM-9-2815-205-24 Technical Manual for M113 Engine 6V53 6V53T Download

Page 269 of 856

CLEANING WARNING Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe vapors. Keep away from heat or flame. Never smoke when using cleaning solvent. Failure to comply may result in injury or death to personnel. Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use only with protective equipment (goggles, face shield, gloves, etc.). Failure to comply may result in injury to personnel. Clean solenoid valve with rag moistened with cleaning solvent. Clean brackets with cleaning solvent. Dry components with compressed air. END OF TASK TEST AND INSPECTION 1. Inspect hoses for cuts, tears, kinks, or damage. 2. Inspect wiring harness for cuts, tears, burns, or damage. 3. Solenoid Test. a. Apply a 24 V dc power supply to the solenoid valve (Figure 4, Item 19) several times and listen for the solenoid valve to “click" to determine if it functions. If there is no indication of valve movement, replace unit. b. Disconnect power supply from solenoid valve (Figure 4, Item 19). 19 24 Vdc + - MAINT_118 Figure 4. Air Box Heater Solenoid Test. END OF TASK TM 9-2815-205-24 0043 0043-7