TM-9-2815-205-24 Technical Manual for M113 Engine 6V53 6V53T Download
Page 257 of 856
CLEANING WARNING Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe vapors. Keep away from heat or flame. Never smoke when using cleaning solvent. Failure to comply may result in injury or death to personnel. Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use only with protective equipment (goggles, face shield, gloves, etc.). Failure to comply may result in injury to personnel. Clean fuel solenoid valve with rag moistened with cleaning solvent. Clean brackets with cleaning solvent. Dry components with compressed air. END OF TASK TEST AND INSPECTION 1. Inspect hoses for cuts, tears, kinks, or damage. 2. Inspect wiring harness for cuts, tears, burns, or damage. 3. Test solenoid. a. Apply a 24 V dc power source to solenoid valve (Figure 5, Item 2) and listen for valve to “click" to confirm if valve is opening and closing as power is applied. If no indication of movement is present, replace solenoid valve. b. Disconnect power source from solenoid valve (Figure 5, Item 2). 2 24 Vdc + - MAINT_110 Figure 5. Air Box Solenoid Test. END OF TASK TM 9-2815-205-24 0042 0042-5