CLEANING WARNING Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe vapors. Keep away from heat or flame. Never smoke when using cleaning solvent. Failure to comply may result in injury, illness, or death to personnel. Compressed air used for cleaning purposes will not exceed 30 PSI (207 kPa). Use only with protective equipment (goggles, face shield, gloves, etc.). Failure to comply may result in injury to personnel. Wash shell assembly and filter body thoroughly with dry cleaning solvent and dry with compressed air. END OF TASK INSPECTION-ACCEPTANCE AND REJECTION CRITERIA Examine shell assembly for cracks or hardening, replace if defective. END OF TASK ASSEMBLY NOTE A cast letter “P" (primary) is on top of strainer head. The filter element, small gasket, and large gasket are provisioned together. 1. Fuel primary filter assembly (strainer). a. Place filter element (Figure 1, Item 15) over center stud in shell assembly (Figure 1, Item 14) and push down until seated. b. Place new large gasket (Figure 1, Item 16) in recess of strainer head (Figure 1, Item 17). c. Place new filter element (Figure 1, Item 15) and shell assembly (Figure 1, Item 14) under strainer head (Figure 1, Item 17) and install new gasket (Figure 1, Item 18) and bolt (Figure 1, Item 19). Tighten bolt just enough to prevent fuel leakage. d. Install drain cock (Figure 1, Item 13) in shell assembly (Figure 1, Item 14). e. Install three plugs (Figure 1, Item 20) in strainer head (Figure 1, Item 17). TM 9-2815-205-24 0031 0031-3