TM-9-2815-205-24 Technical Manual for M113 Engine 6V53 6V53T Download
Page 103 of 856
CLEANING - Continued WARNING Cleaning solvent is TOXIC and flammable. Wear protective goggles and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe vapors. Keep away from heat or flame. Never smoke when using cleaning solvent. Failure to comply may result in injury, illness, or death to personnel. 4. With air pressure off, pour 2.5 quarts (2.4 liters) of cleaning solvent into upper port of oil cooler. 5. Slowly apply 20 PSI (138 kPa) of air pressure and allow air to enter oil cooler for 10 minutes. NOTE Refer to local procedures and plans for storage and disposal of drained fluids. 6. Shut off air supply. Remove air line and carefully drain cleaning solvent. 7. Move fabricated machine-threaded plug (Figure 4, Item 39) and air line to upper port in oil cooler (Figure 4, Item 38). 8. Apply air pressure of 20 PSI (138 kPa) to upper port until remaining solvent is forced out of lower port. 9. Invert transmission oil cooler and repeat Steps 4–8 until cleaning solvent comes out clear in each direction. 39 38 MAINT_021 Figure 4. Transmission Oil Cooler Cleaning. END OF TASK TM 9-2815-205-24 0011 0011-5