TM 9-2540-207-14&P 6-32 6.5.40 F4 - VENT AIR OVERHEAT (Design Iteration 3 Only) THE VENT AIR OUTLET TEMPERATURE HAS EXCEEDED A SAFE OPERATING TEMPERATURE OF 345°F (174°C) CHECK/POSSIBLE CAUSE REF. REPAIR 1 CHECK TO SEE IF FAULT OCCURS AT START UP IF FAULT OCCURS AT START UP GO TO STEP 7 2 CHECK THAT ALL DAMPERS IN VEHICLE ARE OPEN OPEN ALL DAMPERS FULLY SWITCH HEATER TO LOW MODE 3 CHECK FOR OBSTRUCTIONS IN FRONT OF HEATER VENTILATION OUTLET REMOVE OBSTRUCTIONS SWITCH HEATER TO LOW MODE 4 CHECK ALL DUCTING CONNECTIONS VEHICLE TM 2.2 2.3 2.7 INSTALL PROPER DUCTING CORRECTLY SWITCH HEATER TO LOW MODE 5 HEATER DID NOT PROPERLY PURGE 2.5 3.5 CHECK ALL ELECTRICAL CONNECTIONS AND PURGE HEATER 3 TIMES. RESTART HEATER 6 DEFECTIVE VENT SENSOR REPLACE VENT SENSOR RING RESTART HEATER 7 DEFECTIVE LOGIC BOARD REPLACE LOGIC BOARD RESTART HEATER 8 DEFECTIVE HEAT EXCHANGER 5.4.1 REPLACE HEAT EXCHANGER RESTART HEATER