TM-9-2540-207-14&P Sustainment Manual for A20 Heater for M113 2540-01-396-2826 Download
Page 134 of 288
TM 9-2540-207-14&P 5-90 Burner Fan Plate Assembly (continued) 10. Install Diagnostic Display (ref. 5.9.2). 11. Attach Wiring Harness connectors for the Fuel Pressure Sensor (J4), and the Diagnostic Display (J2). Ensure all connectors are properly engaged. 12. Attach the Wiring Harness connector for the Burner Fan Driver Board (J3), ensuring the connector is properly engaged. 13. Using a 9/16" open ended wrench, connect the fuel supply to the heater. 14. Connect vehicle power cable to the heater MS Power connector (Control Box Connection). 15. Start the heater and check that there are NO fuel leaks from the fuel connections. 16. Install Top Cover (ref. 5.4.1). Figure 5-23. Fuel Leak Check Points